<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15079</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: timeout moving leading edge cylinder
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check for faulty LEC sensors by using the "lec" command from the diagnostic.  If the sensor is
faulty, use "set al le 0" or "set al les 0" to bypass the sensor and get the customer going.
Arrange for field service.  If the sensor is OK, test the LEC actuator by using "lec on" or
"lec off" and see if any motion occurs.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Clear obstruction near LEC actuator and select RESUME.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty LEC sensor
</Cause>
<Cause>
Faulty LEC actuator
</Cause>
<SeeAlso>
<UnnumberedList>
NVS: al le cal
<Link><LinkAddress>../nvs/al_cal_les.xml</LinkAddress><LinkTitle>NVS: al les</LinkTitle></Link>
<Link><LinkAddress>../commands/lec.xml</LinkAddress><LinkTitle>Command: lec</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:51 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/trendsetter_3244/content/troubleshooting/15079.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>